E-DEUTZ E360 System


PREMIUMPRODUKT FÜR OFF-HIGHWAY-ANWENDUNGEN
- LEISTUNGSSTARK / Systemleistung bis zu 120 kW
- SICHER / Hochspannungssystem nach ISO 26262
- ROBUST / Speziell für Off-Highway-Anwendungen entwickelt
- ÖKONOMISCH / Niedrige Betriebskosten
- KOMPAKT / Formfaktor für Motorräume oder enge Platzverhältnisse
- MODULAR / Flexible Systemkonfigurationen

E-DEUTZ Electric Drive Systems | E360 W40-42 | E360 D40W40-42 | E360 W40-84 | E360 D40W40-84 | |
---|---|---|---|---|---|
System characteristics | |||||
Battery type | Lithium-Ion (NMC) | ||||
Voltage range | V | 300 - 405 | 300 - 405 | 300 - 405 | 300 - 405 |
Nominal battery capacity | kWh | 42.2 | 42.2 | 84.4 | 84.4 |
E-Motor power (cont. / peak (30s)) | kW | 40 / 80 | 2x 40 / 80 | 40 / 80 | 2x 40 / 80 |
E-Motor speed (rated / max.) | rpm | 2.800 / 10.000 | |||
Charging power | kW | 22 | 22 | 22 | 22 |
Board net supply | kW | 1.5 @ 12 V or 1.1 @ 24 V | |||
Power take off (DC-PTO) | kW | Optional: 7 kW & 10 kW @ 400 V | |||
Communication to application | | J1939 | |||
Included components | | HV-Battery, Powertrain control unit, Inverter, E-Motor, Onboard charger, DCDC, Power distribution unit, Cooling system (excl. HV-Battery), HV-Wiring | |||
Modularity | | 2x DC-PTO, HV-Battery cooling system, LV plug set | |||
Ambient conditions | |||||
Ambient temperature[1] | °C | -35 ... +50 | |||
Altitude range | m | -500 ... +4000 | |||
Relative humidity | % | 0 - 95 | |||
IP protection class | | IP6k9k | |||
Weight (without mountings) | kg | tbd | tbd | tbd | tbd |
Standards | |||||
CE-Conformity | | EU-Declaration of Conformity | |||
Safety | | EN 1175, EN 62619, EN 62485-6, EN 62620, ECE R 100 (Rev.2), ISO 26262, EN 60730-1 | |||
Transport | | EN 62281, UN 38.3 | |||
EMC | | ECE R 10, CISPR 25, EN 61000-6-2, ISO 11452, EN 12895, EN ISO 13766-1, EN ISO 13766-2, EN ISO 14982, EN ISO 14982-1, EN ISO 14982-2 | |||
Legal registration | German Batter Act | ||||
Shock & vibration | ISO 12405-3 | ||||
Additional standards & norms | | ISO 16750 |